Skip to content

Hayward CAT Controller pH Sensor Probe 24 Inch Cable

✓ Hayward Authorized Dealer
✓ Includes Manufacturer Warranty
✓ Installation Available Upon Request
✓ 30-Day Return Policy Guarantee

$429.00

Notify me when back in stock

Hayward CAT Controller pH Sensor Probe, 24-inch cable (W3PRO15-2). OEM replacement pH electrode for Hayward CAT and HCC series chemical automation pool controls. 1/2" NPT ABS body, BNC connector. Designed for compact equipment rooms where controller and flow cell are in close proximity.

  • SKU: W3PRO15-2
  • OEM pH replacement probe for Hayward CAT and HCC series controllers
  • 24-inch cable for installations where the controller and flow cell are within close reach
  • Compatible with CAT1000, CAT3500, CAT4000, CAT5000, CAT5500, HCC1000, HCC2000
  • Direct replacement; same connector and port threading as factory-installed probe
  • 1/2" NPT injection-molded ABS body; color-coded BNC connector
  • Two-point calibration via CAT controller interface (pH 7.0 and 4.0 buffers)
  • Do not extend or splice the cable; added impedance distorts the pH signal
  • Measure the routed cable path before ordering; use the 10-foot version if the run exceeds 22 inches
  • Recommended replacement interval: every 12 to 24 months

Hayward CAT Controller pH Probe (W3PRO15-2): OEM Replacement for CAT and HCC Series Pool Controls

The W3PRO15-2 is the factory pH sensor for Hayward CAT and HCC series chemical automation. It plugs directly into the controller's pH input with no adapters or modifications. The 24-inch cable suits compact equipment rooms where the flow cell and controller cabinet are side by side. Install in a flow cell or bypass sample cell on the pool return line, downstream of filtration and chemical injection points, for accurate continuous pH measurement.

24-Inch Cable: Is It the Right Length?

Measure the actual routed cable path from the flow cell pH port to the controller's pH input before ordering. The 24-inch version is appropriate when that distance is 18 to 22 inches with service slack. For longer runs, use the 10-foot version. Never splice or extend the cable.

Hayward CAT Controller pH Probe 24-Inch Specifications

SKU
W3PRO15-2
Measurement
pH (potential of hydrogen)
Cable Length
24 inches (2 feet)
Connector
BNC (color-coded)
Body
1/2" NPT injection-molded ABS
Compatible Controllers
CAT1000, CAT3500, CAT4000, CAT5000, CAT5500, HCC1000, HCC2000
Calibration
Two-point (pH 7.0 and 4.0 buffer solutions) via controller interface
Installation
Flow cell or bypass sample cell on pool return line, after filtration
Best-Fit Installation
Compact equipment rooms; controller and flow cell in close proximity
Replacement Interval
Every 12 to 24 months

Frequently Asked Questions

Is the 24-inch cable version the same probe as the 10-foot version?

Yes. Same sensing element, electrode technology, and BNC connector. The only difference is cable length.

What calibration buffers do I need?

Use fresh, unexpired NIST-traceable pH 7.0 and 4.0 buffer solutions. Expired buffers are a common cause of calibration error. After calibration, verify the controller's displayed pH against a handheld photometric test kit; agreement within 0.1 to 0.2 pH units is acceptable.

How should I store the probe during seasonal shutdown?

Store in a manufacturer-recommended probe storage solution or pH 4.0 buffer in a sealed cap. Never store dry, and never store in distilled or deionized water.

Should I replace the ORP probe at the same time?

Replacing both probes in a single service visit is the most efficient approach. The matching ORP probe is available separately.