Hayward CAT Controller pH Sensor Probe 24 Inch Cable
✓ Hayward Authorized Dealer
✓ Includes Manufacturer Warranty
✓ Installation Available Upon Request
✓ 30-Day Return Policy Guarantee
Hayward CAT Controller pH Sensor Probe, 24-inch cable (W3PRO15-2). OEM replacement pH electrode for Hayward CAT and HCC series chemical automation pool controls. 1/2" NPT ABS body, BNC connector. Designed for compact equipment rooms where controller and flow cell are in close proximity.
- SKU: W3PRO15-2
- OEM pH replacement probe for Hayward CAT and HCC series controllers
- 24-inch cable for installations where the controller and flow cell are within close reach
- Compatible with CAT1000, CAT3500, CAT4000, CAT5000, CAT5500, HCC1000, HCC2000
- Direct replacement; same connector and port threading as factory-installed probe
- 1/2" NPT injection-molded ABS body; color-coded BNC connector
- Two-point calibration via CAT controller interface (pH 7.0 and 4.0 buffers)
- Do not extend or splice the cable; added impedance distorts the pH signal
- Measure the routed cable path before ordering; use the 10-foot version if the run exceeds 22 inches
- Recommended replacement interval: every 12 to 24 months
Hayward CAT Controller pH Probe (W3PRO15-2): OEM Replacement for CAT and HCC Series Pool Controls
The W3PRO15-2 is the factory pH sensor for Hayward CAT and HCC series chemical automation. It plugs directly into the controller's pH input with no adapters or modifications. The 24-inch cable suits compact equipment rooms where the flow cell and controller cabinet are side by side. Install in a flow cell or bypass sample cell on the pool return line, downstream of filtration and chemical injection points, for accurate continuous pH measurement.
24-Inch Cable: Is It the Right Length?
Measure the actual routed cable path from the flow cell pH port to the controller's pH input before ordering. The 24-inch version is appropriate when that distance is 18 to 22 inches with service slack. For longer runs, use the 10-foot version. Never splice or extend the cable.
Hayward CAT Controller pH Probe 24-Inch Specifications
Frequently Asked Questions
Is the 24-inch cable version the same probe as the 10-foot version?
Yes. Same sensing element, electrode technology, and BNC connector. The only difference is cable length.
What calibration buffers do I need?
Use fresh, unexpired NIST-traceable pH 7.0 and 4.0 buffer solutions. Expired buffers are a common cause of calibration error. After calibration, verify the controller's displayed pH against a handheld photometric test kit; agreement within 0.1 to 0.2 pH units is acceptable.
How should I store the probe during seasonal shutdown?
Store in a manufacturer-recommended probe storage solution or pH 4.0 buffer in a sealed cap. Never store dry, and never store in distilled or deionized water.
Should I replace the ORP probe at the same time?
Replacing both probes in a single service visit is the most efficient approach. The matching ORP probe is available separately.